Typical size in relation to sewer pipe size

Reinforced Manhole Ring to BS.5911 PT200
Click here to view diagram
Heavy Duty Cover Slab to BS.5911 PT200
Click here to view diagram
For terminal and straight through manholes only the following applies:- Chamber Diameter
a. Where depth to invert level does not exceed 1.4 metres, 900 millimetres diameter chamber rings shall be used.
b. Where depth to invert level does not exceed 2.4 metres, 1050 millimetres diameter chamber rings shall be used.
Note: If the sewer diameter is between the figure shown above then the sizes relative to the larger diameter will apply.
Important Note: Although the above table gives the Diameter of Manhole Ring to be used in relation to
depth and size of pipe being used, it is important to check with your specifer as some authorities specify
1200 Diam minimum size, especially where gases may be present in foul sewers.
|